適用範(fàn)圍:
適用於母線槽、斷路器、電流互感器、變壓器、開(kāi)關(guān)櫃、電纜接頭、導(dǎo)軌及其它電器設(shè)備的溫升試驗(yàn)和電流負(fù)載試驗(yàn)。
計(jì)時(shí)設(shè)定範(fàn)圍:0.001S——9999999.999S,精度:0.001S。
Temperature rise of dedicated current source Scope:
For busbar, circuit breakers, current transformers, transformers, switchgear, cables, connectors, and other electrical equipment rail temperature rise test and the current load test.
1 Features:
1) Built-high configuration IPC, imports 15 inches large TFT LCD touch-screen operation, the test without any external auxiliary equipment, automatic control, fool-operation, fast, simple and convenient:
2). Steady flow with an automatic system, equipped with USB, R485, R232 variety of interfaces, easy plug U disk, printers and other equipment. Long-distance transmission remote control terminal operation and running.
3). Uses the most current power electronics technology, imported high-precision sensors, anti-interference ability, high output accuracy up to 0.2
4). Simply set the target current without the need of manual controls, just set the test voltage, current and step length, eliminating the need for manual pressure regulator, manual recording, depicting curves tedious labor, reduce labor intensity and improve working efficiency. After work can also be viewed on a computer the data can be read.
5) Includes current, temperature, lowest and highest values, exceeding the limit value has automatic alarm function. With reliable overcurrent, overvoltage, overheating and short circuit, and other self-protection.
6). Equipped with precision adjustment menu, the user can adjust the error.
7) User-friendly interface, the software user-friendly, full-featured, easy to complete verification work, with current, temperature recorded wave analysis functions, and the current, temperature waveform storage, more intuitive analysis of current versus temperature values. All data and analysis of the test results at a glance.
8) can be displayed throughout the three-phase current curve, up to 120-channel temperature (based on customer selected) curve. Available with micro-printer, you can always print the scene graph and test data.
9) can be customized according to user requirements test modules, software free upgrades for life
Temperature rise of dedicated current source 2 main technical parameters:
Power Input: AC 380/220V ± 10% 50Hz.
◆ long output 0 ~ 50000A current.
Current accuracy: 0.2.
◆ to three phase output 0-50000A AC high current; while the output phase can also be output separately for each phase. Current output can be set arbitrarily combined and multi-level machine output.
◆ outlet voltage :0-1V-2V-4V-6V-8V-10V-12V-24V automatically selected combinations.
◆ The current can be smooth and steady continuously adjustable, precision 0.2; output current is the standard sine wave, tiny glitches, power system requirements than standard indicators, the ripple factor is less than 3%. Intersect each phase angle of 120 degrees.
Current waveform distortion THD 1% design standards far higher than the national standard "GB14048.2-14".
Protection settings: overcurrent, overvoltage
◆ Temperature :0-300 ℃ Accuracy 0.1 ℃ degrees
Time setting range: 0.001S - 9999999.999S, accuracy: 0.001S.
1 Features:
1) Built-high configuration IPC, imports 15 inches large TFT LCD touch-screen operation, the test without any external auxiliary equipment, automatic control, fool-operation, fast, simple and convenient:
2). Steady flow with an automatic system, equipped with USB, R485, R232 variety of interfaces, easy plug U disk, printers and other equipment. Long-distance transmission remote control terminal operation and running.
3). Uses the most current power electronics technology, imported high-precision sensors, anti-interference ability, high output accuracy up to 0.2
4). Simply set the target current without the need of manual controls, just set the test voltage, current and step length, eliminating the need for manual pressure regulator, manual recording, depicting curves tedious labor, reduce labor intensity and improve working efficiency. After work can also be viewed on a computer the data can be read.
5) Includes current, temperature, lowest and highest values, exceeding the limit value has automatic alarm function. With reliable overcurrent, overvoltage, overheating and short circuit, and other self-protection.
6). Equipped with precision adjustment menu, the user can adjust the error.
7) User-friendly interface, the software user-friendly, full-featured, easy to complete verification work, with current, temperature recorded wave analysis functions, and the current, temperature waveform storage, more intuitive analysis of current versus temperature values. All data and analysis of the test results at a glance.
8) can be displayed throughout the three-phase current curve, up to 120-channel temperature (based on customer selected) curve. Available with micro-printer, you can always print the scene graph and test data.
9) can be customized according to user requirements test modules, software free upgrades for life
Temperature rise of dedicated current source 2 main technical parameters:
Power Input: AC 380/220V ± 10% 50Hz.
◆ long output 0 ~ 50000A current.
Current accuracy: 0.2.
◆ to three phase output 0-50000A AC high current; while the output phase can also be output separately for each phase. Current output can be set arbitrarily combined and multi-level machine output.
◆ outlet voltage :0-1V-2V-4V-6V-8V-10V-12V-24V automatically selected combinations.
◆ The current can be smooth and steady continuously adjustable, precision 0.2; output current is the standard sine wave, tiny glitches, power system requirements than standard indicators, the ripple factor is less than 3%. Intersect each phase angle of 120 degrees.
Current waveform distortion THD 1% design standards far higher than the national standard "GB14048.2-14".
Protection settings: overcurrent, overvoltage
◆ Temperature :0-300 ℃ Accuracy 0.1 ℃ degrees
Time setting range: 0.001S - 9999999.999S, accuracy: 0.001S.
1000A溫升專用大電流發(fā)生器1000A溫升專用大電流發(fā)生器1000A溫升專用大電流發(fā)生器1000A溫升專用大電流發(fā)生器1000A溫升專用大電流發(fā)生器